Ziehl-Neelsen Smear Microscopy versus GeneXpert MTB/RIF for Diagnosing Pulmonary Tuberculosis: A Retrospective Diagnostic Accuracy Study from Nepal

Keywords

Diagnostic accuracy
GeneXpert MTB/RIF
Pulmonary tuberculosis
Rifampicin resistance
Ziehl-Neelsen smear microscopy

How to Cite

1.
Bajracharya K, Sapkota LP, Dhakal R, Balami B. Ziehl-Neelsen Smear Microscopy versus GeneXpert MTB/RIF for Diagnosing Pulmonary Tuberculosis: A Retrospective Diagnostic Accuracy Study from Nepal. J Lumbini Med Coll [Internet]. 2026 Nov. 19 [cited 2026 Nov. 19];14(2):65-70. Available from: https://jlmc.edu.np/index.php/JLMC/article/view/611

Abstract

Introduction: Ziehl-Neelsen (ZN) sputum smear microscopy remains widely used for tuberculosis diagnosis in resource-limited settings, but its sensitivity is limited in paucibacillary disease. GeneXpert MTB/RIF offers higher sensitivity, yet real-world comparative data from Nepal remain scarce.

Methods: This retrospective, record-based cross-sectional study was conducted at Lumbini Medical College and Teaching Hospital, Palpa, Nepal. Records of 643 patients with presumptive pulmonary tuberculosis who underwent paired ZN smear microscopy and GeneXpert MTB/RIF testing were reviewed. Using GeneXpert as the reference standard, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy of ZN smear microscopy were calculated with 95% confidence intervals (Wilson method). Agreement was assessed by Cohen's kappa, and McNemar's test compared paired proportions. Receiver operating characteristic (ROC) curve analysis evaluated ZN smear grade discrimination.

Results: ZN smear microscopy was positive in 42 of 643 participants (6.53%) and GeneXpert in 61 (9.49%). ZN sensitivity was 68.85% (95% CI 56.41–79.06), specificity 100.00% (99.34–100.00), PPV 100.00% (91.62–100.00), NPV 96.84% (95.12–97.97), and overall accuracy 97.05% (95.43–98.10). Agreement was substantial (κ = 0.80; p < 0.001). The area under the ROC curve was 0.844. Rifampicin resistance was detected in 1 of 61 GeneXpert-positive samples (1.64%).

Conclusions: ZN smear microscopy showed high specificity but moderate sensitivity, missing one-third of GeneXpert-positive cases. GeneXpert MTB/RIF should remain the preferred initial diagnostic test where capacity allows.

PDF
HTML

Supplementary Files

Supplementary Materials

References

1. World Health Organization. Global tuberculosis report 2024. Geneva: World Health Organization; 2024. Available from: https://iris.who.int/handle/10665/379339

2. Frieden TR, Sterling TR, Munsiff SS, Watt CJ, Dye C. Tuberculosis. Lancet. 2003 Sep 13;362(9387):887-99. doi: 10.1016/S0140-6736(03)14333-4. PMID: 13678977. Available from: https://pubmed.ncbi.nlm.nih.gov/13678977/ and https://doi.org/10.1016/S0140-6736(03)14333-4

3. Abdelaziz MM, Bakr WM, Hussien SM, Amine AE. Diagnosis of pulmonary tuberculosis using Ziehl-Neelsen stain or cold staining techniques? J Egypt Public Health Assoc. 2016 Mar;91(1):39-43. doi: 10.1097/01.EPX.0000481358.12903.af. PMID: 27110859. Available from: https://pubmed.ncbi.nlm.nih.gov/27110859/ and https://doi.org/10.1097/01.EPX.0000481358.12903.af

4. Chandra TJ, Selvaraj R, Sharma YV. Same day sputum smear microscopy for the diagnosis of pulmonary tuberculosis: Ziehl-Neelsen versus fluorescent staining. J Family Med Prim Care. 2015 Oct-Dec;4(4):525-8. doi: 10.4103/2249-4863.174273. PMID: 26985410; PMCID: PMC4776603. Available from: https://pubmed.ncbi.nlm.nih.gov/26985410/ and https://doi.org/10.4103/2249-4863.174273

5. Slim-Saidi L, Mehiri-Zeghal E, Ghariani A, Tritar F. Nouvelles méthodes de diagnostic de la tuberculose [New methods of diagnosis in tuberculosis]. Rev Pneumol Clin. 2015 Apr-Jun;71(2-3):110-21. French. doi: 10.1016/j.pneumo.2015.02.002. PMID: 25754128. Available from: https://pubmed.ncbi.nlm.nih.gov/25754128/ and https://doi.org/10.1016/j.pneumo.2015.02.002

6. Elbrolosy AM, El Helbawy RH, Mansour OM, Latif RA. Diagnostic utility of GeneXpert MTB/RIF assay versus conventional methods for diagnosis of pulmonary and extra-pulmonary tuberculosis. BMC Microbiol. 2021 May 13;21(1):144. doi: 10.1186/s12866-021-02210-5. PMID: 33980173; PMCID: PMC8117635. Available from: https://pubmed.ncbi.nlm.nih.gov/33980173/ and https://doi.org/10.1186/s12866-021-02210-5

7. Pandey P, Pant ND, Rijal KR, Shrestha B, Kattel S, Banjara MR, Maharjan B, Kc R. Diagnostic Accuracy of GeneXpert MTB/RIF Assay in Comparison to Conventional Drug Susceptibility Testing Method for the Diagnosis of Multidrug-Resistant Tuberculosis. PLoS One. 2017 Jan 12;12(1):e0169798. doi: 10.1371/journal.pone.0169798. PMID: 28081227; PMCID: PMC5231346. Available from: https://pubmed.ncbi.nlm.nih.gov/28081227/ and https://doi.org/10.1371/journal.pone.0169798

8. Prakash AK, Datta B, Tripathy JP, Kumar N, Chatterjee P, Jaiswal A. The clinical utility of cycle of threshold value of GeneXpert MTB/RIF (CBNAAT) and its diagnostic accuracy in pulmonary and extra-pulmonary samples at a tertiary care center in India. Indian J Tuberc. 2018 Oct;65(4):296-302. doi: 10.1016/j.ijtb.2018.05.021. PMID: 30522616. Available from: https://pubmed.ncbi.nlm.nih.gov/30522616/ and https://doi.org/10.1016/j.ijtb.2018.05.021

9. Umair M, Siddiqui SA, Farooq MA. Diagnostic Accuracy of Sputum Microscopy in Comparison With GeneXpert in Pulmonary Tuberculosis. Cureus. 2020 Nov 8;12(11):e11383. doi: 10.7759/cureus.11383. PMID: 33312784; PMCID: PMC7725198. Available from: https://pubmed.ncbi.nlm.nih.gov/33312784/ and https://doi.org/10.7759/cureus.11383

10. Held M, Laubscher M, Workman L, Zar HJ, Dunn R. Diagnostic accuracy of GeneXpert MTB/RIF in musculoskeletal tuberculosis: High sensitivity in tissue samples of HIV-infected and HIV-uninfected patients. S Afr Med J. 2017 Sep 22;107(10):854-858. doi: 10.7196/SAMJ.2017.v107i10.11186. PMID: 29022528. Available from: https://pubmed.ncbi.nlm.nih.gov/29022528/ and https://doi.org/10.7196/SAMJ.2017.v107i10.11186

11. Singh UB, Singh M, Sharma S, Mahajan N, Bala K, Srivastav A, Singh KJ, Rao MVV, Lodha R, Kabra SK. Expedited diagnosis of pediatric tuberculosis using Truenat MTB-Rif Dx and GeneXpert MTB/RIF. Sci Rep. 2023 Apr 28;13(1):6976. doi: 10.1038/s41598-023-32810-2. PMID: 37117209; PMCID: PMC10147673. Available from: https://pubmed.ncbi.nlm.nih.gov/37117209/ and https://doi.org/10.1038/s41598-023-32810-2

12. Buderer NM. Statistical methodology: I. Incorporating the prevalence of disease into the sample size calculation for sensitivity and specificity. Acad Emerg Med. 1996 Sep;3(9):895-900. doi: 10.1111/j.1553-2712.1996.tb03538.x. PMID: 8870764. Available from: https://pubmed.ncbi.nlm.nih.gov/8870764/ and https://doi.org/10.1111/j.1553-2712.1996.tb03538.x

13. Mase SR, Ramsay A, Ng V, Henry M, Hopewell PC, Cunningham J, Urbanczik R, Perkins MD, Aziz MA, Pai M. Yield of serial sputum specimen examinations in the diagnosis of pulmonary tuberculosis: a systematic review. Int J Tuberc Lung Dis. 2007 May;11(5):485-95. PMID: 17439669. Available from: https://pubmed.ncbi.nlm.nih.gov/17439669/

14. Crampin AC, Floyd S, Mwaungulu F, Black G, Ndhlovu R, Mwaiyeghele E, Glynn JR, Warndorff DK, Fine PE. Comparison of two versus three smears in identifying culture-positive tuberculosis patients in a rural African setting with high HIV prevalence. Int J Tuberc Lung Dis. 2001 Nov;5(11):994-9. PMID: 11716350. Available from: https://pubmed.ncbi.nlm.nih.gov/11716350/

15. Warren JR, Bhattacharya M, De Almeida KN, Trakas K, Peterson LR. A minimum 5.0 ml of sputum improves the sensitivity of acid-fast smear for Mycobacterium tuberculosis. Am J Respir Crit Care Med. 2000 May;161(5):1559-62. doi: 10.1164/ajrccm.161.5.9908063. PMID: 10806154. Available from: https://pubmed.ncbi.nlm.nih.gov/10806154/ and https://doi.org/10.1164/ajrccm.161.5.9908063

16. Abraham PR, Sharma VD, Shivannavar CT. Diagnosis of TB from smear & culture negative sputum specimens by IS 6110 based PCR. Indian J Med Res. 2012;135(2):249-51. PMID: 22446870; PMCID: PMC3336859. Available from: https://pubmed.ncbi.nlm.nih.gov/22446870/

17. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977 Mar;33(1):159-74. doi: 10.2307/2529310. PMID: 843571. Available from: https://pubmed.ncbi.nlm.nih.gov/843571/ and https://doi.org/10.2307/2529310

18. Ojha S, Adhikari A, Adhikari S, Khanal S, Kalwar CS, Panta OP. Comparative evaluation of sputum microscopy and Xpert MTB/RIF assay for tuberculosis detection and rifampicin resistance surveillance in Biratnagar, Nepal. Microbiol Spectr. 2026 Apr 7;14(4):e0246025. doi: 10.1128/spectrum.02460-25. PMID: 41811027; PMCID: PMC13055257. Available from: https://pubmed.ncbi.nlm.nih.gov/41811027/ and https://doi.org/10.1128/spectrum.02460-25

19. Rimal R, Shrestha D, Pyakurel S, Poudel R, Shrestha P, Rai KR, Ghimire GR, Rai G, Rai SK. Diagnostic performance of GeneXpert MTB/RIF in detecting MTB in smear-negative presumptive TB patients. BMC Infect Dis. 2022 Apr 1;22(1):321. doi: 10.1186/s12879-022-07287-5. PMID: 35365080; PMCID: PMC8973748. Available from: https://pubmed.ncbi.nlm.nih.gov/35365080/ and https://doi.org/10.1186/s12879-022-07287-5

20. Lama C, Adhikari S, Sapkota S, Regmi RS, Ghimire GR, Banjara MR, Ghimire P, Rijal KR. Evaluation of Xpert MTB/RIF Assay, MTB Culture and Line Probe Assay for the Detection of MDR Tuberculosis in AFB Smear Negative Specimens. Diseases. 2022 Oct 6;10(4):82. doi: 10.3390/diseases10040082. PMID: 36278581; PMCID: PMC9624312. Available from: https://pubmed.ncbi.nlm.nih.gov/36278581/ and https://doi.org/10.3390/diseases10040082

21. Van Deun A, Tahseen S, Affolabi D, Hossain MA, Joloba ML, Angra PK, Ridderhof JC, de Jong BC, Rieder HL. Sputum smear microscopy in the Xpert® MTB/RIF era. Int J Tuberc Lung Dis. 2019 Jan 1;23(1):12-18. doi: 10.5588/ijtld.18.0553. PMID: 30567624; PMCID: PMC13007724. Available from: https://pubmed.ncbi.nlm.nih.gov/30567624/ and https://doi.org/10.5588/ijtld.18.0553

22. Burger Z, Aung HT, Seifert M, Mar TT, Harris V, Colman RE, Rodwell TC, Aung ST. Contributions of GeneXpert® to TB diagnosis in Myanmar. Int J Tuberc Lung Dis. 2022 Sep 1;26(9):875-879. doi: 10.5588/ijtld.22.0009. PMID: 35996278; PMCID: PMC9423018. Available from: https://pubmed.ncbi.nlm.nih.gov/35996278/ and https://doi.org/10.5588/ijtld.22.0009

23. Swets JA. Measuring the accuracy of diagnostic systems. Science. 1988 Jun 3;240(4857):1285-93. doi: 10.1126/science.3287615. PMID: 3287615. Available from: https://pubmed.ncbi.nlm.nih.gov/3287615/ and https://doi.org/10.1126/science.3287615

24. Paudel S, Padmawati RS, Ghimire A, Yonzon CL, Mahendradhata Y. Feasibility of Find cases Actively, Separate safely and Treat effectively (FAST) strategy for early diagnosis of TB in Nepal: An implementation research. PLoS One. 2021 Oct 26;16(10):e0258883. doi: 10.1371/journal.pone.0258883. PMID: 34699542; PMCID: PMC8547636. Available from: https://pubmed.ncbi.nlm.nih.gov/34699542/ and https://doi.org/10.1371/journal.pone.0258883

25. Zifodya JS, Kreniske JS, Schiller I, Kohli M, Dendukuri N, Schumacher SG, Ochodo EA, Haraka F, Zwerling AA, Pai M, Steingart KR, Horne DJ. Xpert Ultra versus Xpert MTB/RIF for pulmonary tuberculosis and rifampicin resistance in adults with presumptive pulmonary tuberculosis. Cochrane Database Syst Rev. 2021 Feb 22;2(2):CD009593. doi: 10.1002/14651858.CD009593.pub5. PMID: 33616229; PMCID: PMC12045032. Available from: https://pubmed.ncbi.nlm.nih.gov/33616229/ and https://doi.org/10.1002/14651858.CD009593.pub5

Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

Copyright (c) 2026 Kishor Bajracharya, Laxmi Prasad Sapkota, Riwaaz Dhakal, Bardan Balami